Cool-Lite
Solarcontrol unit configuration (6 – 16 -6) | Visible Light | Energy Factors | Solar Factor | Shading Coefficient | U – value | Project | |||||
Outer Leaf | Inner Leaf | Total Light Transmission % | External Reflection % | Direct Transmission % | External Reflection % | Absorption % | g value | SC | Air W/m² K | Argon (90%) W/m² K | Example |
COOL-LITE XTREME 60/28 | CLEAR FLOAT | 60 | 14 | 25 | 39 | 34 | 0.28 | 0.32 | 1.3 | 1.0 | |
COOL-LITE SKN174 | CLEAR FLOAT | 68 | 11 | 37 | 28 | 32 | 0.41 | 0.47 | 1.4 | 1.1 | Hull Royal Infirmary |
COOL-LITE SKN176 | CLEAR FLOAT | 70 | 14 | 35 | 34 | 31 | 0.37 | 0.43 | 1.3 | 1.0 | Archbishop Blanch School |
COOL-LITE SKN165 | CLEAR FLOAT | 60 | 16 | 30 | 32 | 37 | 0.33 | 0.38 | 1.3 | 1.0 | Northern Design Centre |
COOL-LITE SKN154 | CLEAR FLOAT | 50 | 18 | 24 | 34 | 41 | 0.27 | 0.31 | 1.3 | 1.0 | Ryhope Mental Hospital |
COOL-LITE SKN144 | CLEAR FLOAT | 40 | 20 | 20 | 31 | 48 | 0.23 | 0.26 | 1.4 | 1.1 | Redcar Leisure Centre |
COOL-LITE XTREME 50/22 | CLEAR FLOAT | 50 | 17 | 20 | 38 | 42 | 0.22 | 0.25 | 1.3 | 1.1 |